ASTM D, Bearing Capacity of Soils for Static Load & Spread Footings – Download as PDF File .pdf), Text File .txt) or read online. Find the most up-to-date version of ASTM D at Engineering In each increment; the load stays static for 15 minutes according to ASTM D 94 specification. The results showed that the plate settlements of the soil under.

Author: Kazisho Zuktilar
Country: Kuwait
Language: English (Spanish)
Genre: Music
Published (Last): 25 January 2008
Pages: 467
PDF File Size: 20.17 Mb
ePub File Size: 5.9 Mb
ISBN: 345-5-69399-534-4
Downloads: 50893
Price: Free* [*Free Regsitration Required]
Uploader: Mazuzilkree

Digital Transformation may be defined in a number of different ways by analysts or enterprise software vendors.

The Eng-Tips staff will check this out and take appropriate action. In addition to the continuous listing of all time, load, and settlement data for each test, the report shall include at least the followings:. The plate bearing load test shall asmt discontinued if any of the following occurs: Subcommittees responsible for standards develop can withdraw a standard if they consider that it has limited continued use value.

Promoting, selling, recruiting, coursework and thesis posting is forbidden. As an alternative, three small concrete footings of the size mentioned or larger can be cast in-situ.

Plate Bearing Test | Plate Load Testing – Site Testing Services LTD

The subsidence induced by the ground plate are simultaneously detected by centesimal or digital data acquisition systems, integral with a frame of reference outside the area of influence of the applied load.

Such footing must have a depth of not less than two thirds of their width. Register now while it’s still free! This test was rarely done for this purpose anymore. Plate Load testing is usually used for the verification of the bearing capacity of the land of the substrate, of the foundation layer and the base layer of the flooring, although it is not uncommon to its use to investigate the bearing capacity of the soil surface or to the state compaction of granular materials and road surfaces.

  AUDIOCONTROL 4XS PDF

Reasons such as off-topic, e1194, flames, illegal, vulgar, or students posting their homework. The applied load shall be measured using calibrated electronic load cell. The details of equipment including the certificates of instrument and copies of calibration charts from approved agency and setup for conducting the plate load test shall be submitted for the approval by the Engineer before commencement of the test.

Asttm Now Defense manufacturing is all about project manufacturing and project accounting. Resources Digital Transformation may be defined in a number of different ways by analysts or enterprise software vendors. It’s easy to join and it’s free. The two active ones are for pavement design, but you can gain the same type of info. Click Here to join Eng-Tips and talk with other members! For bearing plates, three circular steel bearing plates, not less than 25mm in thickness and varying in diameter from mm to mm including the minimum and maximum diameter specified or square steel bearing plates of equivalent area.

The plate load test shall ast carried out at locations as shown in the drawings or as directed by the Engineer using approved equipment. Close this window and log in.

Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden.

Join your peers on the Internet’s largest technical engineering professional community. The load test consists in transmitting to the soil to be tested and the subsequent increasing load increments, detecting simultaneously the sagging and therefore allows to directly determine a form of deformation or compressibility of the soil.

ASTM makes withdrawn standards available for informational purposes. In rock, plates larger than mm diameter may be used, depending on the jointing frequency. Download Now White Paper: There are two active plate load tests that can be used Students Click Here Join Us!

  ENTHRALLED BY MORETTI PDF

Precise leveling optical survey to accuracy of 0.

NEW! Static plate load tester HMP PDGpro according to ASTM D1194/1195/1196, DIN 18134

Miscellaneous Apparatus required, including loading columns, steel shims, and other construction tools and equipment required for preparation of the test pits and loading apparatus. A standard may be withdrawn with or without replacement. Are you an Engineering professional?

The reference beam and measuring devices should be protected from the direct rays of the sun and from wind by means of tarpaulins or other forms of shelter, to minimize errors of measurement which can easily arise from these causes. The Settlement-Recording Devices, such as dial e1194 should be able to measure to an accuracy of at least 0.

The Hydraulic or Mechanical Jack Assembly should have sufficient capacity to provide and maintain the maximum estimated load but not less than 50 tons in any case. Defense manufacturing is all about project manufacturing and project accounting. By joining you are opting in to receive e-mail. Thank you for helping keep Eng-Tips Forums free from inappropriate posts.

Of fundamental importance, in any case, is the use of the proper contrast medium whose mass is a function of the expected load. The load transmission takes place via the application of a force by means of a hydraulic system of thrust, of a circular plate.